| Search results: |
Showing 1 of 1 |
|
 |
 |
3M2091
3M P100 Hepa Filter. Use with 3M(tm) Facepieces 6000 Series or 3M(tm) Facepieces 7500 Series against a variety of gases, vapors and particulate hazards according to NIOSH approvals.
|
 |
 |
 |
|
|
 |
 |
3M2097
The 3M Particulate Filter, P100 has been developed with your respiratory needs in mind. Specially designed carbon layers help remove nuisance levels of organic vapors. Use with 3M Facepieces 6000 Series or 3M Facepieces 7000 Series with bayonet filter holders.
The 2097 is well suited for a wide range of oil and non-oil based particulate contaminants. Ideal for welding, metal pouring, torch cutting, abatement or as a prefilter for
certain chemical exposures.
|
 |
 |
 |
|
|
 |
 |
3M501
3M Retainer Prefilter.
Used to hold 3M™ Particulate Filters 5N11 and 5P71/07194(AAD) in place on top of 3M™ Respirators 5000 Series and 3M™ Cartridges 6000 Series.
|
 |
 |
 |
|
|
 |
 |
3M502
3M Filter Adapter
Use to attach 3M Particulate Filters 2000 Series and 7093 to the 3M Respirators 5000 Series and 3M Cartridges 6000 Series for a wide variety of applications.
|
 |
 |
 |
|
|
 |
 |
3M5N11
3M Particulate Filter, N95
NIOSH approved for environments containing certain non-oil based particles. Use with 3M™ Respirators 5000 Series or 3M™ Cartridges 6000 Series, and 3M™ Filter Retainer 501.
When properly fitted, use with appropriate cartridges for various applications including spray painting, petrochemical and chemical manufacturing, and pesticide spraying for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use for aerosols containing oil or in environments that are immediately dangerous to life or health (IDLH).
|
 |
 |
 |
|
|
 |
 |
3M5P71
3M Particulate Filter, P95
NIOSH approved for environments containing certain oil and non-oil based particles. Use with 3M™ Respirators 5000 Series or 3M™ Cartridges 6000 Series, and 3M™ Filter Retainer 501.
When properly fitted, use with appropriate cartridges for various applications including spray painting, lacquering, petrochemical and chemical manufacturing, pesticide spraying and agriculture for concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in environments that are immediately dangerous to life or health (IDLH).
|
 |
 |
 |
|
|
 |
 |
3M6001
3M Organic Vapor Cartridge
NIOSH approved against certain organic vapors. Use with 3M™ Half and Full Facepieces 6000 Series and 3M™ Half and Full Facepieces 7000 Series with bayonet style cartridge holders.
Use in a variety of workplace applications, including petrochemical, chemical manufacturing, construction, transportation and electronics. When properly fitted, helps provide respiratory protection from certain organic vapors at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Not for use in environments that are immediately dangerous to life or health (IDLH).
|
 |
 |
 |
|
|
 |
 |
3M6002
3M Acid Gas Cartridge
NIOSH approved against certain acid gases. Use with 3M™ Half and Full Facepieces 6000 Series and 3M™ Half and Full Facepieces 7000 Series with bayonet style cartridge holders.
Use in a variety of applications including chemical manufacturing, glass etching, pulp and paper, and laboratories. When properly fitted, helps provide respiratory protection from chlorine, hydrogen chloride, sulfur dioxide, or chlorine dioxide, or hydrogen sulfide (escape only) at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Not for use in environments that are immediately dangerous to life or health (IDLH).
|
 |
 |
 |
|
|
 |
 |
3M6003
3M Organic Vapor/Acid Gas Cartridge
NIOSH approved against certain organic vapors or acid gases. Use with 3M Half and Full Facepieces 6000 Series and 3M™ Half and Full Facepieces 7000 Series with bayonet style cartridge holders.
Use in a variety of applications, including pharmaceutical, petrochemical, utilities, aluminum reduction, chemical manufacturing, laboratories, and pulp and paper. When properly fitted, helps provide respiratory protection from certain organic vapors, chlorine, hydrogen chloride, sulfur dioxide, or hydrogen sulfide (escape only) or hydrogen fluoride at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Not for use in environments that are immediately dangerous to life or health (IDLH).
|
 |
 |
 |
|
|
 |
 |
3M6004
3M Ammonia Methylamine Cartridge
NIOSH approved against ammonia and methylamine. Use with 3M Half and Full Facepieces 6000 Series and 3M™ Half and Full Facepieces 7000 Series with bayonet style cartridge holders.
Use in a variety of applications including agriculture, chemical manufacturing, laboratories and the food industry. When properly fitted, helps provide respiratory protection from ammonia and methylamine at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Not for use in environments that are immediately dangerous to life or health (IDLH).
|
 |
 |
 |
|
|
 |
 |
3M6005
3M Formaldehyde/Organic Vapor Cartridge
NIOSH approved against formaldehyde and certain organic vapors. Use with 3M Half and Full Facepieces 6000 Series and 3M™ Half and Full Facepieces 7000 Series with bayonet style cartridge holders.
Use in a variety of applications, including laboratories, wood processing, carpet manufacturing, and primary metals manufacturing. When properly fitted, helps provide respiratory protection from formaldehyde and certain organic vapors at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Not for use in environments that are immediately dangerous to life or health (IDLH). OSHA requires that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde.
|
 |
 |
 |
|
|
 |
 |
3M6006
3M™ Multi Gas/Vapor Cartridge
NIOSH approved against certain organic vapors, acid gases, ammonia, methylamine or formaldehyde. Use with 3M™ Half and Full Facepieces 6000 Series and 3M™ Half and Full Facepieces 7000 Series with bayonet style cartridge holders.
Use in a variety of applications, including petrochemical and chemical processing, utilities, pharmaceuticals, mining and primary metals. When properly fitted, helps provide respiratory protection from certain organic vapors, chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide, hydrogen sulfide (escape only), ammonia, methylamine, formaldehyde or hydrogen fluoride at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Not for use in environments that are immediately dangerous to life or health (IDLH). OSHA requires that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde.
|
 |
 |
 |
|
|
 |
 |
3M60921
3M Cartridge/Filter, Organic Vapor/P100
NIOSH approved against certain organic vapors and particulates. Use with 3M Half and Full Facepieces 6000 Series and 3M™ Half and Full Facepieces 7000 Series with bayonet style cartridge holders.
Use in a variety of applications including petrochemical, construction, transportation and chemical manufacturing. When properly fitted, helps provide respiratory protection from certain organic vapors and particulates at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use for sandblasting or in environments that are immediately dangerous to life or health (IDLH).
|
 |
 |
 |
|
|
 |
 |
3M60922
3M™ Cartridge/Filter, Acid Gas/P100
NIOSH approved against certain acid gases and particulates. Use with 3M™ Half and Full Facepieces 6000 Series and 3M™ Half and Full Facepieces 7000 Series with bayonet style cartridge holders.
Use in a variety of applications including chemical manufacturing, glass etching, pulp and paper, and laboratories. When properly fitted, helps provide respiratory protection from chlorine, hydrogen chloride, sulfur dioxide, or chlorine dioxide, or hydrogen sulfide (escape only) and particulates at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in environments that are immediately dangerous to life or health (IDLH).
|
 |
 |
 |
|
|
 |
 |
3M60923
3M Cartridge/Filter, Organic Vapor/Acid Gas/P100
NIOSH approved against certain organic vapors, acid gases and particulates. Use with 3M Half and Full Facepieces 6000 Series and 3M™ Half and Full Facepieces 7000 Series with bayonet style cartridge holders.
Use in a variety of applications including petrochemical, laboratories, pharmaceutical and chemical manufacturing. When properly fitted, helps provide respiratory protection from certain organic vapors, chlorine, hydrogen chloride, sulfur dioxide, or hydrogen sulfide (escape only) or hydrogen fluoride and particulates at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in environments that are immediately dangerous to life or health (IDLH).
|
 |
 |
 |
|
|
 |
 |
3M60924
3M™ Cartridge/Filter, Ammonia/ Methylamine/ P100
NIOSH approved against ammonia, methylamine and certain particulates. Use with 3M™ Half and Full Facepieces 6000 Series and 3M™ Half and Full Facepieces 7000 Series with bayonet style cartridge holders.
Use in a variety of applications including agriculture, chemical manufacturing, laboratories and the food industry. When properly fitted, helps provide respiratory protection from ammonia, methylamine and certain particulates at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use for sandblasting or in environments that are immediately dangerous to life or health (IDLH).
|
 |
 |
 |
|
|
 |
 |
3M60925
3M Cartridge/Filter 60925, Formaldehyde/Organic Vapor/P100
NIOSH approved against formaldehyde, certain organic vapors and particulates. Use with 3M Half and Full Facepieces 6000 Series and 3M™ Half and Full Facepieces 7000 Series with bayonet style cartridge holders.
Use in a variety of applications, including laboratories, wood processing, carpet manufacturing, and primary metals manufacturing. When properly fitted, helps provide respiratory protection from formaldehyde, certain organic vapors and particulates at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in environments that are immediately dangerous to life or health (IDLH). OSHA requires that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde.
|
 |
 |
 |
|
|
 |
 |
3M60926
3M™ Cartridge/Filter, Multi Gas/Vapor/P100
NIOSH approved against certain organic vapors, acid gases and particulates. Use with 3M™ Half and Full Facepieces 6000 Series and 3M™ Half and Full Facepieces 7000 Series with bayonet style cartridge holders.
Use in a variety of applications, including petrochemical and chemical processing, utilities, pharmaceuticals, mining and primary metals. When properly fitted, helps provide respiratory protection from certain organic vapors and particulates, chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide, hydrogen sulfide (escape only), ammonia, methylamine, formaldehyde or hydrogen fluoride at concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with full facepieces. Full facepieces must be quantitatively fit tested to claim assigned protection factor above 10 in negative pressure mode. Do not use in environments that are immediately dangerous to life or health (IDLH). OSHA requires that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde.
|
 |
 |
 |
|
|
 |
 |
3M60928
3M Cartridge/Filter 60928, Organic Vapor/Acid Gas/P100
NIOSH approved for certain organic vapors, acid gases and particulates. 3M recommended for use against radioiodine or methyl bromide with 3M Half and Full Facepieces with bayonet cartridge connections.
While NIOSH does not have a test procedure to certify air purifying filters against radioiodine or methyl bromide, this combination cartridge is recommended by 3M for use against radioiodine or methyl bromide at ambient concentrations up to 5 ppm and for not more than one shift. For more information, see Technical Data Bulletin #146 "Use Recommendations for 3M 60928 Cartridge/Filter." Do not use in environments that are immediately dangerous to life or health (IDLH).
|
 |
 |
 |
|
|
 |
 |
7580P100
P100 Particulate Filter – (99.97% Minimum Filter Efficiency)
Air Purifying Respirators with filters provide respiratory protection against aerosols by removing dusts, mists, fumes, fibers, and other particles. Filters do not remove gases or vapors, or correct for oxygen deficiency.
End of service life for filters is normally determined by the increase in breathing resistance sensed by the user.
|
 |
 |
 |
|
|
 |
 |
7583P100
Organic Vapor, Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Fluoride, Chlorine Dioxide Cartridge, with P100 Particulate Filter (99.97% Minimum Filter Efficiency).
|
 |
 |
 |
|
|
 |
 |
75FFP100
North Pancake: Low profile P100 filter for use under welding helmets. 99.97% filter efficiency for all particulates.
|
 |
 |
 |
|
|
 |
 |
75SCP100
Defender™ Multi Purpose Cartridge Organic Vapor,Chlorine,Hydrogen Chloride,Sulfur Dioxide,Hydrogen Sulfide (Escape),Hydrogen Fluoride,Chlorine Dioxide,Ammonia,Methylamine and Formaldehyde Cartridge with P100 Particulate Filter (99.97% Minimum Filter Efficiency)
|
 |
 |
 |
|
|
|
|
© 2005 Fit-rite Safety Wear Inc.
|
 |
|
|
|